본문 바로가기

Redundant7

Connecting the PROFINET ring to S7-1500 Connecting the PROFINET ring to S7-1500 Introduction You connect the PROFINET ring between the two R-CPUs at the RJ45 sockets of PROFINET interfaces X1 P1 R and X1 P2 R. Requirements • One of the two connections of the PROFINET ring between the two R-CPUs must not contain any other IO devices, switches or other PROFINET devices apart from transparent media converters. • The default setting in ST.. 2023. 12. 2.
S7-1500_Wiring Rules and regulations for operation Introduction The S7-1500R/H redundant system is a plant and system component. Special rules and regulations must be adhered to in line with the area of application. This section gives an overview of the key rules for integration of the redundant system into a plant or system. Please follow these rules when connecting the S7-1500R/H redundant system. Specific a.. 2023. 12. 2.
Communication System and device IP addresses Device IP addresses For the interfaces of the CPUs and the IO devices to be accessible, the interfaces require IP addresses that are unique within the network (device IP addresses). MAC addresses The CPUs have a unique MAC address for each interface and its ports. The MAC addresses of the PROFINET ports are needed for the LLDP protocol, for example for the neighbor.. 2023. 12. 2.
Displaying faults in an IO device Displaying faults in an IO device The various components of the S7-1500R/H redundant system are connected over PROFINET/Industrial Ethernet (IE). The devices detect faults in their modules (for example IO device ET 200SP) and send diagnostics data to the assigned CPU. The CPU analyzes this diagnostic information and notifies the connected display media. The information analyzed is shown in graph.. 2023. 12. 2.
PLC REDUNDANT SYSTEM(S7-1500H) S7-1500H structure and operating principle S7-1500H 구조 및 작동 원리 The figure below shows the typical structure of the S7-1500H redundant system. 아래 그림은 S7-1500H 이중화 시스템의 전형적인 구조를 보여줍니다. ① CPU 1517H-3 PN ② PROFINET cable (PROFINET ring) ③ Redundancy connections (fiber-optic cables) ④ IO device ⑤ Switch The S7-1500H redundant system consists of: S7-1500H 이중화 시스템은 다음과 같이 구성됩니다: • Two CPUs S7-1500H ① •.. 2023. 11. 29.
PLC REDUNDANT SYSTEM(S7-1500R) S7-1500R/H redundant systems tolerate the failure of one of the two CPUs or an interruption in the PROFINET ring. The S7-1500R and S7-1500H systems differ in structure, configuration limits and performance. S7-1500R/H 이중화 시스템은 두 CPU 중 하나의 장애 또는 중단을 허용합니다 PROFINET 링에서 S7-1500R 및 S7-1500H 시스템은 구조, 구성, 한계 와 성능이 다릅니다 Each PROFINET ring may only contain one R-system or one H-system at a time. A combi.. 2023. 11. 29.
S7-1500R/H redundant system #1 시스템 개요 3 3.1 S7-1500R/H 이중화 시스템이란? S7-1500R/H 이중화시스템 S7-1500R/H 이중화 시스템의 경우 CPU가 한 쌍이 되므로 이중화가 발생합니다. 두 CPU는 동일한 프로젝트 데이터와 동일한 사용자 프로그램을 병렬로 처리합니다. 두 CPU는 CPU가 두 개의 이중화 연결을 통해 동기화됩니다. CPU 하나에 장애가 발생하면 다른 CPU가 프로세스 제어를 유지합니다. 이중화 자동화 시스템 사용 목표 이중화 자동화 시스템의 목적은 생산 가능성을 줄이는 것입니다 두 시스템을 병렬로 운영하여 다운타임을 줄일 수 있습니다. 안전한 자동화 시스템의 목표 페일 세이프 자동화 시스템의 목적은 생명, 환경 및 자본을 보호하는 것입니다 안전한 상태로 안전하게 종료됩니다. 참조 원칙적으로 .. 2023. 11. 16.